Generac generator runs then shuts off - The shut down after 30 minutes uses may be when the a/c cycles off. The generator then speeds up the frequency goes too high and the monitoring cct shuts the generator down. In the manual is a procedure to adjust the frequency. You will need a meter to measure frequency. 1.

 
1. Overloading — The most common reason behind this problem is the overloading on the generator. When a generator is overloaded; it stops to work and shuts down. This problem is commonly.... Citizens bank hyannis ma

Honda 5hp 2600 runs good for 20 to 30 min. then shuts off. After waiting 15 to 20 min. engine will start again and repeats the above problem. Oil level is good … Chris, it is a 16k lp carrier model aspas1cca015 serial# 1106v14935. The unit starts for about 20 seconds and then shuts down with flashing red overspeed light. It will start right back up and does same thing most of the time. Occasionally it will start back up and run until I shut it off.It will start and run about 45 or so minutes and then shut off. It will restart, but will only run 10 minutes and shut off. ... I have an RV Generac generator 6500. After running for a period of time, the choke will come on and cause the generator to sputter and run rough. Also, the exhaust is blue and it uses a lot of oil.It starts fine, runs for 5 seconds then shuts off. ... generac generators support. i have a two year old GP6500 that will not start. it seems to not even be turning over. I checked the [lug. it is good. ... Generac Model 00G007043, New, Low Oil Pressure Alarm, generator shut off. Oil Level is fine. I suspect the sensor is bad.Chris, it is a 16k lp carrier model aspas1cca015 serial# 1106v14935. The unit starts for about 20 seconds and then shuts down with flashing red overspeed light. It will start right back up and does same thing most of the time. Occasionally it will start back up and run until I shut it off.If this happens, when you open the gas cap, you will hear a rush of air into the tank. The fuel cap is defective and must be replaced. If you think you have these symptoms, it is best to call our tech line for evaluation and/or replacement. Our tech line can be reached 24 hours a day, seven days a week by calling 1-877-338-0999.At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode. Generator will start and run. Allow generator to run and warm up for a few ...Tape plastic over your car window frame as a quick fix when your window is broken, or you are unable to shut the window. This can be necessary if you find yourself the victim of a ...The most popular reason behind this issue is the overloading of the generator. Water Levels: After a few seconds, water levels in the radiator may also cause the system to turn off. Place it in a radiator filled with water. Allow it a routine after a month to check the water level in the radiator.Generac generator in my camper runs great for 15 minutes then shuts off - Answered by a verified Technician We use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them.3.1) My Motorhome Generator Won't Start, or Starts then Stalls. 3.2) Check Your Motorhome's Fuel Level. 3.3) Check the Condition of Your Motorhome's Coach Battery. 3.4) Check Your Generator's Oil Level. 3.5) Check the Main Circuit Breaker. 3.6) Confirm that Fuel is Getting to the Carburetor. 3.7) Check the Spark Plug.Hello. I have a Generac 7550 EXL generator. It cranks up and runs about 5-8 seconds and then shuts down. It will crank back up fairly easily but does same thing. I've cleaned the carb and checked fuel feed line. Carb gets gas and the bowl still has gas in it when it shuts down (so apparently not a float issue). Any input? Thank you very much.Posted 12/21/2013 19:43 (#3536955 - in reply to #3536709) Subject: Re: Generac Generator shutting off after startup. Faunsdale, AL. Could be any one of several things, but most likely a bad circuit board, broken wire etc. They will also shut down like that from low oil pressure, (usually has to time out a delay ), no AC voltage build up ...Jul 24, 2010. Posts. 29. I just had the carb cleaned on this, it was out of the RV when I got it. As I got everything hooked up and pressed start after priming, it fired right up. However, when I let the start button go, it dies in short order. It's an older generator, most likely a 93 or 94. Model 09557-4, Series NP30g.Originally Posted by georgebonord. Hi Everyone. We live in the South where it gets hot in the summer. The heat causes us to run the gasoline Onan 5500 generator to power the A/C. We have a 2003 HR Vacationer on a W22 Workhorse chassis. The generator will shut down after 2-3 hours of run time. It will restart but only for a few seconds.10. Spark plug. The spark plug is one of the most important parts of the generator and plays a vital role in starting the generator. If the spark plugs are dirty and fail, your generator will stop right after starting and shut down within seconds. Open the spark plug and check its condition.There may be a fault in the engine due to rodents. They like to take up residence in your generator and, in lieu of food, they'll chew on wires and hoses. The block heater may not be working. Low oil pressure. Emissions issue, for example diesel exhaust fluid level is low, or noxious emissions have otherwise been detected.Allow the generator to run for a cool-down period of approximately one minute. At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode.10. Spark plug. The spark plug is one of the most important parts of the generator and plays a vital role in starting the generator. If the spark plugs are dirty and fail, your generator will stop right after starting and shut down within seconds. Open the spark plug and check its condition. 1998 Rexair motor home with a Generac Model #GN480 Q55G serial#301011. Starts easy, runs great for about 1 to 2 minuets, then shuts off. Not low on oil. Generator will run as long as I have 12 volts a … read more The most popular reason behind this issue is the overloading of the generator. Water Levels: After a few seconds, water levels in the radiator may also cause the system to turn off. Place it in a radiator filled with water. Allow it a routine after a month to check the water level in the radiator.Marquis Gold Generac HGJAB-900 RV Generator 1) Generator will run with no issues when RV is stationary. Runs for 12, 24 and more hours straight with no issues 2) Shut it off and start within an hour, … read moreNov 6, 2020 ... ... generator is practically new but it has a very strange problem. The problem is that it runs perfectly fine in choke but not at all, off ...A generator starts and then dies due to an empty fuel tank, plugged fuel filter, dirty carburetor, clogged fuel line, bad gas cap, dirty spark plug, faulty ignition coil, low engine …Gas line will be changed to 3/4 " in to gen, with the Generac vibration line then a 36" x 3/4 pipe to 2nd stage regulator. When gen runs for 10 seconds the flow of gas is 10.5" w.c and the RPM is steadyKohler manufactures gas and diesel generators in several different sizes. Although the engines are generally reliable, they can require troubleshooting and maintenance in order to ...You don't need a third-party app to drown out noise. If you want to drown out environmental noise, or you just like having white noise in the background while you work, you should ...Troubleshoot 01: Spark Plug. Assuming you have fuel in the generator, the next thing to check is the spark plug. If the spark plug can't generate a spark, it won't ignite and power the generator. Take out the spark plugs and inspect them. If the spark plugs are damaged, replace them.Its a back up to our newly installed Generac 24kw propane generator. I think I had my air compressor breaker on, this generator won't start it and the compressor kick on and tried to start. I turned it off as close to immediately as I could. Everything was fine for a few hours then the generators rpm went sky high and I ran to shut it off.Troubleshoot 01: Spark Plug. Assuming you have fuel in the generator, the next thing to check is the spark plug. If the spark plug can’t generate a spark, it won’t ignite and power the generator. Take out the spark plugs and inspect them. If the spark plugs are damaged, replace them.First set the genset switch to OFF. Each of those fuses carries 120 volts, so be careful. Using insulated tools, pull both N1 and N2 fuses, and test them with a meter. ... it will only run for about 10 -15 minutes then it shuts down and gives an "overspeed alarm". ... He purchased a Generac 20 kW generator and is running it on propane.3. Locate the power disconnect for the site (service or non-service rated). Flip the switch to the off position. 4. Confirm that power transfer occurs to the generator. This can take between 5 to 20 minutes depending on configured settings. If power is transferred successfully, the generator will turn on and return power to the home.For our RV we have a generac primepact model 02010-0. We run this generator about every 4-6 wks. During our last encounter all was well until we put a load on the generator by turning on the AC. It ra … read moreMy 22kw Generac Generator will NOT shut off. I've tried absolutely everything including checking and pulling the fuses. The generator still would not shut off. ... Although this is a maybe since if it's in a spot where it will run, it would run without the stepper moving Choke off (also powered by the controller)01 - Generator Carburetor. The carburetor might be clogged or have bad fuel in the float bowl. If old fuel was left in the small engine for a long time, some of the volatile ingredients may have evaporated, leaving a thicker, stickier product that is more like varnish or shellac. This sticky fuel can clog up the small jets and ports in the ...01 - Generator Carburetor. The carburetor might be clogged or have bad fuel in the float bowl. If old fuel was left in the small engine for a long time, some of the volatile ingredients may have evaporated, leaving a thicker, stickier product that is more like varnish or shellac. This sticky fuel can clog up the small jets and ports in the ...5) The carburetor is clogged or air locked. If you stored your generator for a long period of time without first draining the carburetor, the odds are high that it may be clogged by old gasoline. To fix this, shut off the fuel valve, and then open the carburetor drain found at the bottom of the carburetor's bowl.The generator was running on propane and when I turn it on now it turns over and runs full throttle for a few seconds and then shuts itself off. Tried switching over the gas as well as checking oil and air filter but thats all. any help would be appreciated. Sounds like a fuel issue, like the bowl is filling and running dry, not keeping up with ...Damaged pole of a multiple rotor or stator may be the other reason of low frequency; Decrease or increase in the supply power system may be a reason for this problem'. Nozzle assembly failure, fuel filter failure, fuel pump failure, excessive unit vibration or a heavy load, etc. are also the key reasons for low frequency.My np 66 g propane generator shuts off when a load is applied. ... I have a 10 KW generac standby generator runs for 10 to 20 seconds and then shuts off on LP does not start when I switch it to natural gas ... Generac generator will start and run. When I turn on the generators brakers the motor does not idel up and it stops running in 10 to 15 ...Generator Keeps Shutting Off. If your generator keeps shutting off, there could be a number of potential causes. Here are a few things you can check. 1. Overloading. If you're running too many appliances or tools that require more power than the generator can provide, it can cause the generator to shut off.Yesterday I double-checked gas flow by removing top test port screw on fuel regulator. Don't have a manometer, but seemed like plenty of gas when gas shut-off valve opened. Tried starting again after reinstalling test port screw and to my surprise it started right up and ran great. Ran it for about 15 minutes then shut down.Check the oil level. Most generators have a dipstick like the one in your car. Pull it out, wipe it off with a rag, then pop it back in. After about 30 seconds, take it out and check whether the oil is above the “empty” mark. If not, go ahead and refill it. Like gasoline, oil can go bad over time.Press and hold the "Test" button on the control panel for 10 seconds. Release the "Test" button and wait for the generator to go through its startup sequence. This may take a few minutes. After the startup sequence is complete, the generator should perform its weekly test as scheduled.Low Oil Level: Generac generators have a safety feature that shuts off the power if the oil level is too low. Check the oil level and add oil if necessary. Faulty Battery: If your Generac generator has an electric start, a faulty battery can prevent it from producing power. Make sure the battery is properly charged and in good condition.Turned auto idle off, restarted fine. I put a load on it (120V 2 hp Air Compressor), it took it fine. Until the compressor turned off, then so did the generator (auto idle still off). Now the generator starts up, runs to what appears to be a higher than normal RPM, puts out a no load 120v voltage of around 42V and shuts off.Im looking for a low oil pressure switch for the generac in my RV. Generator starts and runs for about 10 - 12 seconds then shuts down. I'm assuming it the low oil pressure sensor. Oil and filter are … read moreAt the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode. Generator will start and run. Allow generator to run and warm up for a few ...Got new battery but the unit will not automatically shut off during weekly run cycle now. ... MY STANDBY GENERAC GENERATOR IS RUNNING BECAUSE IF I TURN IT OFF, THE ELECTRICAL OUTLETS IN THE HOUSE GO OFF...EVEN THOUGH THE POWER IS BACK ON IN MY NEIGHBORHOOD. ... manually actuate the switch to backup power position then start the generator ...It starts right up, but shuts down around about 8 seconds. I noticed that if the regulator indicator light comes on, it will continue to run and make power. If the regulator indicator light does not come on, it will not make power, and usually shuts down. Occasionally it will continue to run without making power.It is a Craftsman 15HP B&S Industrial engine with a Generac generator. It runs flawlessly, however I do have a question about the "IDLE CONTROL SWITCH." The switch runs the engine at normal [high] speeds when there is a load present, and at idle [low] speeds when there is no load present. It is supposed to greatly improve fuel economy.Turn the fuel valve on to drain the fuel from the tank, being careful not to overfill the container. 8. When draining is done, turn the fuel valve back off and reconnect the fuel line to the carburetor, being sure to reinstall the hose clamp. 9. Next, locate the carburetor behind the air filter housing. Slide a container under the carburetor.Have Enough Fuel Available. Even if your generator is ready to run, you'll need enough fuel to keep it going in the event of a prolonged outage. Keep at least 10 gallons of fresh gasoline for ...I have a 15KW Generac generator with an automatic transfer switch that will start in the event of a power failure. The switch will transfer to generator power and the generator will run and carry the load for about 15 minutes. Then it stalls. The transfer switch will remain in the generator position.Generac Q-55G Highline, model 09592-3, 5500w, 120/240 mounted in 97 Rexhall Aerbus 30ft class A. starts and runs fine. when i push rocker start/stop switch to stop, engine speed lowers but won't stop. when i push rocker start/stop to start, engine goes back to normal. i pulled spark plug wire to stop.May 2, 2023 Knowledge. In the event that a previously functioning generator suddenly stops working, the first step is to check the levels of both gas and oil to ensure they are …Most generators run off of the same fuel system as the motorhome engine does. With fuel starvation issues, if your motorhome starts and runs, it's the fuel system at the generator that is the issue. The exception is the low full level in the tank. Many motorhomes will stop or not allow a generator to start if the fuel capacity is below a ...17RE8-16-C3 I have tried to shut the generator breaker off and the manually start it and it still shuts off right away after starting The battery charger on it got unplugged and so it drained the battery. And when power went out it didn't even try to start.I have followed the troubleshooting guide for a Generac Generator. Engine starts, runs 10 seconds and cuts off. Have replaced the computer board, control board, oil pressure switch and high temp switch. The unit still starts, runs 10 seconds or less and cuts off.Wait for about half a minute when you switch off the Generator. After waiting, move the generator to its manual position. By doing so, your Generator will switch on. The next step is to test your Generator. Run it for about 4 to 5 minutes in manual mode. Wait for some time, and shut off the Generator again.It doesn't know or care if the engine is shut off or stops turning because the fuel runs out. E J Brown on July 23, 2021 at 9:39 pm I have a Briggs&Stratton 7500 watt an they tell me to not turn off the gas until you turn the generator off first, don't let it run dry because there is a little gas left that might gum up.Gas line will be changed to 3/4 " in to gen, with the Generac vibration line then a 36" x 3/4 pipe to 2nd stage regulator. When gen runs for 10 seconds the flow of gas is 10.5" w.c and the RPM is steadyHello. I have a Generac 7550 EXL generator. It cranks up and runs about 5-8 seconds and then shuts down. It will crank back up fairly easily but does same thing. I've cleaned the carb and checked fuel feed line. Carb gets gas and the bowl still has gas in it when it shuts down (so apparently not a float issue). Any input? Thank you very much.First, make sure the spark plug is in good condition. Next, check the continuity using an ohmmeter. Replace it if you find a break in the continuity. 5. Low Engine Oil Level in the Generac Generator. When the engine oil level is too low, the Generac will shut down to protect the engine from damage.If the system is sort of clever then the voltage climbs to the top of the tolerance range and then the inverter simply reduces its output. If the system is really clever then the generator reduces its output to some minimum and then the inverter starts dialing back. And if you are unlucky then the magic smoke exits the important bits.-JonIf the generator is giving you a countdown delay, that means that it thinks you still do not have power. You can shut the generator off and if you have utility power available the transfer switch should automatically switch back to the utility side. If those fuses are showing good, the lightning strike may have fried the controller in the ...How to Clear the Maintenance Reminder from the Control Panel. Hit the gray ENTER button once, and you will see the following screen asking if service was performed: Control panel prompt asking if service was performed. Hit ENTER. Hit ENTER once more, and the generator will return to normal where only the green “AUTO” light is illuminated.First, make sure the spark plug is in good condition. Next, check the continuity using an ohmmeter. Replace it if you find a break in the continuity. 5. Low Engine Oil Level in the Generac Generator. When the engine oil level is too low, the Generac will shut down to protect the engine from damage.generac guardian starts and runs ok under load but shuts down after 15 min. will restart but shuts down after 10 sec. wait 1 hr. then same chain of events. what are posible causes, or tests to perform …A Generac generator starts and then dies due to an empty fuel tank, plugged fuel filter, dirty carburetor, clogged fuel line, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gas. Learn how to diagnose and fix these 12 problems with easy steps and tips.PostMon Apr 29, 2019 3:14 pm. Hi my name is Craig and I am having a problem with my Rv generator, its a Generac Item # 0047040 Series 4704-0 Serial # 4784860. Its a Guardian 6500 run on gas. The gen starts and runs fine although a little rough at times, but it is not putting out any power. There is no power at the input side of breakers, I ...If it shuts down after 2 seconds, then likely it is the rpm sensor on the flywheel. It can go bad or go out of adjustment. Check the sensor output while running , even if only 2 secs, you should get 0.4-0.6 v AC and the sensor should have 1000 ohms +- 10 % resistance. You can adjust the sensor to flywheel gap down to "one half turn" in …The propane is used in place of gasoline, which is what most generators use. Check to make sure there are no leaks in the tank. If the generator runs then shuts off it may be a temperature issue. Check the oil level and air filter. Examine the device connected to the generator. Open the generator (ensure it is off) and check to make sure the ...Why is the Generac portable generator engine running rough? 1. Make sure there is enough fuel in the generator. Drain the fuel if you suspect it is stale or has been contaminated with water. 2. Ensure the fuel valve is fully open. 3. Check the air filter. Clean or replace if needed.Needless to say, when the engine fails and stops running, the generator automatically shuts down. This is a complex problem and only a professional can fix it. ... If your generator runs then shuts off, it can be due to a jammed fuel valve. If the fuel valve is closed, the generator wouldn't start at all. But, if it starts and then shuts down ...Last Friday the test cycle ran fine as it does every week. Last night we had a 30 second power failure, the generator started and shut down. Then a real power failure due to the storms... The Generator ran for about 20 seconds and shut down. Oil Low and Battery low lights were on. So I added 1/2 quart oil in the dark.It runs then shuts off. Do we need a regulator to reduce the pressure? ... 2013 generac generator 20k with a evolution board. recently hooked up start and runs then shut off it 5 seconds. did a test five on it disconnected the j plug reconnected it with the fuse out then re ...Jul 20, 2023 ... A few weeks ago I worked on a Generac GP7500e that had stopped making power. It ended up having a bad rotor. Today another Generac GP7500e ...My np 66 g propane generator shuts off when a load is applied. ... I have a 10 KW generac standby generator runs for 10 to 20 seconds and then shuts off on LP does not start when I switch it to natural gas ... Generac generator will start and run. When I turn on the generators brakers the motor does not idel up and it stops running in 10 to 15 ...Generac Guardian 15000 Watt whole house standby generator was running fine then shut down instead oversteer started it - Answered by a verified Technician ... I have a 10 KW generac standby generator runs for 10 to 20 seconds and then shuts off on LP does not start when I switch it to ... I have a Generac Guardian 15 KW generator that runs but ...RFguy. The remote unit can start then stop the generator when utility power is present. It can't stop the generator when the generator started to run due to a utility loss. What you're looking for is not easily done. You should shed the load first, then allow a cool down period and then shut the generator down.Since it takes less than a quarter of a second of power loss for PSU to loose power and hard shutting down the PC, possibly causing data corruption on your storage drives. By ATX PSU standard, PSU must be able to keep the PC running for 17 milliseconds (0.017 seconds) when power is cut off. Best PSUs in the world can keep the PC running for 30 ...

Generac generators are known for their reliability and ability to provide backup power during outages. However, like any mechanical device, they can encounter problems from time to.... John deere x300 pto won't engage

generac generator runs then shuts off

It doesn't know or care if the engine is shut off or stops turning because the fuel runs out. E J Brown on July 23, 2021 at 9:39 pm I have a Briggs&Stratton 7500 watt an they tell me to not turn off the gas until you turn the generator off first, don't let it run dry because there is a little gas left that might gum up.6. Start the set and let it run. While it is running, measure the output voltage of the set. With these wires disconnected, then engine should run for longer than 5 minutes. Wile carefully monitoring for engine overheating, or any strange noises (shut it off immediately if either are noted), let the engine run for about 10-15 minutes. 7.I shut the water off and the the fridge and lights came back to normal in about 2-5 minutes. I then turned the toaster on with the fridge running and it did the same thing blackout/brownout then came back a few minutes later keeping the toaster off. During the above the generator stayed running the entire time.The gas cap was replaced about 6 months ago, so I wouldn't consider it high on the suspect list. The outside temperature was about 85 degrees. I'll probably get the gen out Saturday and see how long it runs - and be checking the oil pressure light. Other suggestions welcome. Generator details: Model 09778-4. 5500XL.Press the enter key to turn it off. Allow the generator to sit for 30 seconds. Turn the generator to its manual position to start it. Once the generator starts, let it run for five minutes. After running it for five minutes, turn the generator off. Wait for another 30 seconds. Put the generator in its auto position.Are you wondering why your GENERAC generator with COSense starts but won't keep running? Watch this video to find out why. We'll explain the problem and how ...24kW Generac Generator with 200-Amp Whole House Automatic Transfer Switch. ... and then shuts the generator down. To keep the standby generator lubricated and ready to run, the controller will also exercise the generator on a set schedule. It starts the unit, lets it run for a short period, then shuts it down again. How it Works: Components of ...My generator will only run about five minutes then it dies. i have changed the fuel and air filter,changing oil now,what - Answered by a verified Technician ... I have a generac centurion 17500 gas powered generator.. we have been rimming it for about 6 days and changing the oil and oil filter every 50 hours of use or so All of a …Some models of the 17kw are known for self destruction of the generator end, it won't run if it is not making voltage. Small bits of copper in the bottom of the housing is a telltale. If the later, check for fuel, air, spark and compression. If one of those 4 is missing it won't run. 5 days is a long time for one of those sets.Im looking for a low oil pressure switch for the generac in my RV. Generator starts and runs for about 10 - 12 seconds then shuts down. I'm assuming it the low oil pressure sensor. Oil and filter are … read moreNov 8, 2020 · I have a Generac 15k NG unit, model 0053820, serial# 4652524, 188 hours.It but was last run nearly a year ago. It starts and runs briefly (maybe 5-10 seconds) then shuts off with a flashing overspeed light. At the controller, set the generator to OFF. Remove the 7.5A fuse from the controller. To turn the generator back ON: Install 7.5A fuse in controller. Confirm the generator MLCB (generator disconnect) is OFF (OPEN). At the controller, set the generator to AUTO mode. Generator will start and run. Allow generator to run and warm up for a few ...That was a few weeks ago. I stopped by (the house is vacant for the winter) last week during a storm with a power outage. I expected to see the generator running but instead it was shutdown on Low Voltage. It starts right up and runs for a couple of minutes and then shuts down.- The unit runs for a few seconds and then shuts down in manual mode - Running in automatic mode (setting exercise timer) it starts and shuts down after a few seconds (1 - 2 seconds). Red overspeed light illuminates solid (not blinking)Why is Causes it to stall. How to Fix. Stale Fuel. Gas is less combustible and the engine will have too low of a fuel-to-air ratio for combustion when the choke is off. Turn off fuel valve, drain carburetor bowl, disconnect fuel line from carburetor and drain gas from tank. Clogged or Restricted Main Jet.01 - Generac Pressure Washer Carburetor. The carburetor might be clogged. A clogged carburetor is most commonly caused by leaving fuel in the pressure washer for a long period of time. Over time, some of the ingredients in the fuel may evaporate, leaving behind a thicker, stickier substance. This sticky fuel can clog up the carburetor and cause ...Remove all loads before turning the generator off. First, turn off all appliances, lights, and items being powered by the generator. Then, unplug the items from the generator's receptacles and allow the generator to cool. Once you've done this, it is safe to turn the generator off. NEVER turn the generator off while loads are applied.Honda generator eu6500is starts and runs for a few seconds then shuts down, like power off. Would not start initially only on carb cleaner cleaned carb throughly and checked oil pressure sensor by inpluggjng and the same result. It's like brand new last ran 2 yes ago what else would cause the shut down.Here's what I've been buying this week. Try not get burned, and generate above market returns. Here's what I've been buying this week....HOOD You run toward the fir....